Esta página todavía no está traducida por completo: donde falta la traducción se muestra el inglés. Leer la versión en inglés →

Gutter & downspout calculator

ft
ft

Distancia horizontal de la canaleta a la cumbrera (más cualquier muro o techo más alto que le escurra encima).

in/hr

De su código local o de un mapa de lluvias — no es un número que este sitio pueda saber.

gpm
— gpm de escurrimiento máximo

Guarde estos resultados

Enviamos este único correo a través de nuestro proveedor de correo y no guardamos su dirección.

Runoff arithmetic on the figures you type. Rainfall intensity and downspout capacity come from your local code and the product maker — this page does not size gutters for you or replace a drainage design.

Type the roof footprint that drains to the gutter, the design rainfall intensity for your area, and — when you have it — what one downspout is rated to carry. The calculator gives the peak flow the gutter has to handle and how many downspouts that takes, spread evenly along its length.

Ejemplo resuelto

One side of a gable roof: 40 ft long, 15 ft from eave to ridge in plan = 600 sq ft. The local design storm is 4 in/hr. Runoff = 600 × 4 × 0.0104 = 24.9 gpm. If one downspout is rated for 12 gpm, that is 24.9 ÷ 12 = 2.08 — round up to 3 downspouts, one about every 13 ft 4 in of gutter (or one at each end and one in the middle).

Metric: 12 m × 4.5 m = 54 m² at 100 mm/h is 54 × 100 ÷ 3600 = 1.5 L/s.

Pruebe un ejercicio

Escurrimiento

A 1,500 sq ft roof plan in a 3 in/hr design storm. Peak runoff in US gallons per minute?

gpm

¿Se atascó? Una pista

Área × intensidad × 0.0104.

Metric runoff

A 180 m² roof in a 75 mm/h storm. Peak runoff in litres per second?

L/s

¿Se atascó? Una pista

1 mm de lluvia sobre 1 m² es exactamente 1 litro.

Quick referencefor roof runoff

Imperial
gpm = sq ft × in/hr × 0.0104 · 1,000 sq ft at 1 in/hr ≈ 10.4 gpm
Métrico
L/s = m² × mm/h ÷ 3,600 · 1 mm on 1 m² = 1 L
Downspouts
runoff ÷ capacity of one, rounded UP
Spacing
gutter length ÷ downspouts (keep each in its share of the roof)

La fórmula

runoff = plan area × intensity  ·  downspouts = ⌈runoff ÷ capacity⌉

Preguntas

How much water comes off a roof in a storm?
Plan area times rainfall intensity. One inch an hour on 1,000 square feet of roof is about 10.4 US gallons a minute; in metric, 1 mm an hour on 1 m² is 1 litre an hour, so 100 m² at 36 mm/h is 1 litre a second. Use the plan (bird’s-eye) area the gutter drains, not the sloped surface.
Where do I get the rainfall intensity?
From your local building code, your municipality or a national rainfall-intensity map, for the storm length and return period your code uses. It varies a lot by region, so this calculator does not guess it — type the figure for your area.
How much does one downspout carry?
It depends on its size, shape, the outlet and the gutter feeding it. Gutter and downspout makers publish a capacity (or a roof area per downspout at a given intensity); some codes give one too. Type that figure and the calculator gives the count.
Should the steep part of the roof count for more?
Wind-driven rain on a steep roof can put more water in the gutter than the plan area suggests, and some design guides add a pitch factor for that. If yours does, multiply the plan area by it before typing — or type the adjusted area directly.

Herramientas relacionadas

¿Ve algo incorrecto en esta página? Repórtelo

Incluiremos esta página y los números que usted escribió. Leemos cada reporte, pero no podemos responder.

Gracias — su reporte fue enviado.